Giordano, Gerardo (2008) Development and test of tunable mechanical monolithic horizontal accelerometer for low frequency seismic noise measurement. [Tesi di dottorato] (Inedito)

[img]
Anteprima
PDF (Tesi Dottorato)
tesi_giordano_gerardo.pdf

Download (6MB) | Anteprima
[error in script] [error in script]
Tipologia del documento: Tesi di dottorato
Lingua: English
Titolo: Development and test of tunable mechanical monolithic horizontal accelerometer for low frequency seismic noise measurement
Autori:
AutoreEmail
Giordano, Gerardogerardo.giordano@na.infn.it
Data: 30 Novembre 2008
Istituzione: Università degli Studi di Napoli Federico II
Dipartimento: Scienze fisiche
Scuola di dottorato: Rischio sismico
Dottorato: Rischio sismico
Ciclo di dottorato: 21
Coordinatore del Corso di dottorato:
nomeemail
Gasparini, Paolopaolo.gasparini@na.infn.it
Tutor:
nomeemail
Barone, Fabriziofabrizio.barone@na.infn.it
Milano, Leopoldoleopolo.milano@na.infn.it
Data: 30 Novembre 2008
Parole chiave: Seismometer , Accelerometer , low frequency , Folded Pendulum , Optical Lever , Michelson Interferometer , Control
Settori scientifico-disciplinari del MIUR: Area 02 - Scienze fisiche > FIS/07 - Fisica applicata (a beni culturali, ambientali, biologia e medicina)
Area 02 - Scienze fisiche > FIS/06 - Fisica per il sistema terra e il mezzo circumterrestre
Depositato il: 16 Nov 2009 09:16
Ultima modifica: 30 Apr 2014 19:36
URI: http://www.fedoa.unina.it/id/eprint/3365
DOI: 10.6092/UNINA/FEDOA/3365

Abstract

This thesis describes a mechanical horizontal monolithic sensor for geophysical applications. The instrument is basically a monolithic tunable folded pendulum, shaped with precision machining and electric-discharge-machining, that can be used both as seismometer and, in a force-feedback configuration, as accelerometer. It is a very compact instrument, very sensitive in the low-frequency seismic noise band, with a very good immunity to environmental noises, whose main characteristics are the tunability of the resonance frequency and the integrated laser optical readout, consisting of an optical lever and an interferometer. The theoretical sensitivity curves are in a very good agreement with the measurements. A direct comparison of its performances with the STS-2 ones shows that better performances have been reached with the interferometric readout, about 10e-12 m/sqrt(Hz) in the band [0.01,10] Hz as seismometer. The first results as accelerometer (force feed-back configuration) are also presented and discussed.